หากคุณมีคำถามใดๆ โปรดติดต่อฝ่ายบริการลูกค้า 02 2748661-3 หรืออีเมล์ contact@lableader.co.th
if you have any question, please contact customer support 02 2748661-3 email to contact@lableader.co.th
xเครื่องนึ่งฆ่าเชื้อ ขนาดความจุ 60 ลิตร ทำอุณหภูมิสูงสุด (Max Temp.) 130 องศาเซลเซียส
Gene-8C2 is an Isothermal fluorescence PCR instrument, it is a compact, lightweight, low cost, standalone, sensitive instrument suitable for field based and point of care diagnostic applications The Gene-8C is a portable instruments that provides measurement of one fluorophore, and the Gene-8C2provide measurement of two fluorophores. We designed these to run any isothermal amplification method that employs target detection by fluorescence measurement. The Gene-8C2 boast low powe requirements and includesa rechargeagle Lithium-polymer battery that can keep it running for 2-5 hours Gene-8C2 have a 7inch touch screen. Realtime temperature and fluorescence data are displayed graphically and in real-time during a run and all of the data are held in the instrument’s large internal Flash memory. These data are permanently stored and can be reviewed at any time after the run has finished or uploaded to a PC or an android mobile via USB link or WIFI
-External size (WxDxH) 1800x800x2340 mm -Internal size (WxDxH) 1620x670x750 mm -Good acid and alkali resistance function. -Motorize front glass window. -Adjustable 9 levels air speed. -Microprocessor control system and LED display. -Double-layer structure: 1.2 mm sheet metal surface, melamine board inward. -Protection class I -Protection type IP 20 -PVC exhaust duct diameter 300 mm.
-External size (WxDxH) 1800x840x2100 mm -Internal size (WxDxH) 1680x730x740 mm -Chemical resistance phenolic resin. -Motorize front glass window. -Adjustable 9 levels air speed. -Microprocessor control system and LED display. -alarm when filter working time 3500 hours. -Built-in centrifugal blower
-Micro-controller controls the internal temperature within 22±2ºC. -High accuracy sensor and direct air flow system ensure even temperature distribution. -Formed in place CFC free PUF insulation ensures temperature stability and reduced energy consumption. -Audio visual alarm for temperature deviation beyond ±2ºC and power failure. -Motion failure alarm when the agitator fails to operate. -Automatic agitator and UV lamp stop when door is open. -LED display for easy of reading. -UV lamp for sterilization.
The SUNTEX Microprocessor automatic water still is available with output of 4L/hr or 8L/hr, and can be benched or wall mounted. The water still produces the very highest quality pyrogen free water. Purity is also assured through the borosilicate glass(Boilers and Condensers) construction and the use of durable, silica sheathed heating elements.
Features Adjustable temperature to 1150º C Stability of temperature: ±1º C Homogeneity of temperature: ±5º C The system has a digital control for temperature/time by microprocessor. Control P.I.D. with thermocouple type K. Nine user free programs. Each one has a waiting time to start. 18 different segments can be edited and modified in all user free programs. Every segment has a slope and a maintenance time Heating by thermo-ceramic plates. Double body door Fibre-ceramic thermo insulation with low thermo conductivity and low density material. Safety system that disconnect the electrical heater when the door is opened. Include the exhaust device to allow the fumes and gases go outside.
Biological Safety Cabinet (class II, A2) Three protection: operator, sample and environment. Airflow system: 70% air re-circulation, 30% air exhaust. Suitable for working with microbiological research in the absence of volatile or toxic chemicals and radionuclide.
-External size (WxDxH) 1840x800x2200 mm -Internal size (WxDxH) 1620x570x870 mm -It is safer to use anti-corrosive water tap. -Microprocessor control system and LCD display. -Made of porcelain white PP, resistance to strong acid, alkali and anti-corrosion. -Front window which is made of thick transparent toughened glass maximize light and visibility inside the fume hood, providing a bright and open working environment.
Co-using Angle & Swing rotor, Ergonomically arranged and designed, RPM/RCF auto calculating, Changing term of timer during operation, memory for saving experiment condition, BLDC Motor, Easy to keypad, Compact design
Shaking Water Baths Shaking Water Baths (also known as Reciprocating Water Baths), are designed to handle a wide variety of applications. These baths can be used effectively in molecular biology protocols (such as hybridization), bacterial culturing, as well as in solubility and metabolism studies. The SHEL LAB Models SWBR17 and SWBR27 Reciprocating Water Baths are designed to deliver precise temperature control and a smooth reciprocal shaking motion. The oscillator control is independent, allowing the baths to also be used for regular constant temperature water bath applications such as thawing, warming reagents, or general incubation. Both the SWBR17, and SWBR27 Shaking Water Baths offer an adjustable stroke length ( 0.5″, 1″ or 1.5″), giving the user the ability to affect the degree of agitation. With a RPM range of 20-200, these versatile reciprocating water baths are sure to meet many application needs. Shaking Water Bath Applications Hybridization Applications, Cell Cultures, Cell Aeration, Increasing Solubility Rates, Molecular Biology Assays, Bacterial Cultures.
Features Natural air convection. Adjustable temperature from room temperature +5º C to 80º C. Temperature regulation by microprocessor Delay & incubation time programmable between 0 and 99h Homogeneity and stability according to DIN-12880. Safety according to EN-61010-1, EN-61010-2-010. Heating by electric resistance, assembled in independent chamber, allowing an optimal stabilization of temperature. External case epoxy resin painted. Inner chamber, inner side door and trays made in stainless steel AISI 304. Silicone sealing gasket. Adjustable aeration device. Connection to PC (USB) Control software (optional) Environment: 0 to 50ºC, max RH 85%
DNP-1500-MP Protein-Nitrogen distiller based on Kjeldahl method. Automatic, to analyse proteic nitrogen in raw material samples or processed material for food industry. Specific methods availables. Results complies with regulations: EN/ISO, AOAC.
Ambient +5°C to 99°C Bench-Top Shaking Incubator IS-RSD3 Model IS-RSD3 Speed Range 0rpm, 30~400rpm
Features Forced air convection. Adjustable temperature from room temperature + 5º C to 250º C. Temperature regulation by microprocessor. Delay & incubation time programmable between 0 and 99h Temperature homogeneity and stability according to DIN-12880. Safety according to EN-61010-1, EN-61010-2-010. Heating by electric resistance, assembled in independent chamber, allowing an optimal stabilization of temperature. External case epoxy resin painted. Inner chamber, inner side door and trays made in stainless steel AISI 304. Silicone sealing gasket. Adjustable aeration device.
-Micro-controller controls the internal temperature within 22±2ºC. -High accuracy sensor and direct air flow system ensure even temperature distribution. -Formed in place CFC free PUF insulation ensures temperature stability and reduced energy consumption. -Audio visual alarm for temperature deviation beyond ±2ºC and power failure. -Motion failure alarm when the agitator fails to operate. -Automatic agitator and UV lamp stop when door is open. -LED display for easy of reading. -UV lamp for sterilization.
Features Adjustable temperatures: from 35º C to 200º C. Temperature homogeneity:± 4º C Temperature stability:± 1º C Temperature display accuracy:± 2º C Maximum admissible vacuum: 0,01 mbar. Safety according to: EN-61010-1, EN-61010-2-010. Double safety glass against implosions according to regulations Safety thermostat: class 2 incorporated from factory. Time and temperature controller: digital by microprocessor. Temperature probe: Pt 100 Class A Epoxy resin oven painted external case. Interior made in polished stainless steel AISI 304.
Biological Safety Cabinet (class II, A2) Three protection: operator, sample and environment. Airflow system: 70% air re-circulation, 30% air exhaust. Suitable for working with microbiological research in the absence of volatile or toxic chemicals and radionuclide.
Autoclave (Sterilizer) An autoclave is a strong heated container used for chemical reactions and other processes in need of high amounts of pressure and temperature. Sterilization Autoclaves have a variety of uses in the fields of microbiology, medicine, podiatry, tattooing, body piercing, veterinary science, mycology, funeral homes, dentistry, prosthetics fabrications, etc.
Biological Safety Cabinet (class II, A2) Three protection: operator, sample and environment. Airflow system: 70% air re-circulation, 30% air exhaust. Suitable for working with microbiological research in the absence of volatile or toxic chemicals and radionuclide.
-External size (WxDxH) 1100x750x2200 mm -Internal size (WxDxH) 940x600x650 mm -Moterized front window. -Two layers laminated toughened glass >5mm, anti UV. -Time reserve function. -Interlock funtion. -Microprocessor control system. -HEPA filter life and UV life indicator. -0% air re-circulation, 100% air exhaust. -Automatic air speed adjustable with filter block. -Most accessories are standard. No need to pay more, save your money. -Work area surrounded by negative pressure, it can ensure maximum safety in work area. -Visual&Audio alarm when filter replacement, window over height, abnormal air flow velocity. -PVC exhaust duct, diameter 300 mm.
Features Natural air convection. Adjustable temperature from room temperature +5º C to 80º C. Temperature regulation by microprocessor Delay & incubation time programmable between 0 and 99h Homogeneity and stability according to DIN-12880. Safety according to EN-61010-1, EN-61010-2-010. Heating by electric resistance, assembled in independent chamber, allowing an optimal stabilization of temperature. External case epoxy resin painted. Inner chamber, inner side door and trays made in stainless steel AISI 304. Silicone sealing gasket. Adjustable aeration device. Connection to PC (USB) Control software (optional) Environment: 0 to 50ºC, max RH 85%
-External size (WxDxH)1300x750x2250 mm -Internal size (WxDxH) 1150x600x650 mm -Moterized front window. -Two layers laminated toughened glass >5mm, anti UV. -Time reserve function. -Interlock funtion. -Microprocessor control system. -HEPA filter life and UV life indicator. -0% air re-circulation, 100% air exhaust. -Automatic air speed adjustable with filter block. -Most accessories are standard. No need to pay more, save your money. -Work area surrounded by negative pressure, it can ensure maximum safety in work area. -Visual&Audio alarm when filter replacement, window over height, abnormal air flow velocity. -PVC exhaust duct, diameter 300 mm.
Max 130°C Vertical Autoclave 100L. Material External : Steel Plate with Powder Heating Coated Dimension External (W×D×H ) : 550x680x1070mm 650x780x1150 mm
CO2 Incubators The SHEL LAB CO2 Incubator family includes the following design features and the longest warranty period on the market – a five year limited warranty on most models: Infrared (IR) CO2 Sensor is extremely quick to recover CO2 levels after door openings and ensures superior pH stability Unique air jacket design provides excellent temperature uniformity of +/-0.25°C at 37°C Humidity levels, maintained through evaporation, of up to 95% Data logging capabilties
Co-using Angle & Swing rotor, Ergonomically arranged and designed, RPM/RCF auto calculating, Changing term of timer during operation, memory for saving experiment condition, Fast Cooling, AC induction Motor Cooling System, Lid latch by motor preventing imbalance of sample.
Features Forced air convection. Adjustable temperature from room temperature + 5º C to 250º C. Temperature regulation by microprocessor. Delay & incubation time programmable between 0 and 99h Temperature homogeneity and stability according to DIN-12880. Safety according to EN-61010-1, EN-61010-2-010. Heating by electric resistance, assembled in independent chamber, allowing an optimal stabilization of temperature. External case epoxy resin painted. Inner chamber, inner side door and trays made in stainless steel AISI 304. Silicone sealing gasket. Adjustable aeration device.
Pathological sampling bench is widely used in hospital pathology department, pathology laboratory, etc. Reasonable ventilation system protects operator away from the harmful gas produced by the formalin during sampling. The hot & cold water system ensures it can adapt work in different climates.
AHS-DRY Raypa autoclaves Intended use: Suitable to sterilize: wrapped or unwrapped solids, small porous elements and hollow elements type B (slightly deep and broad cavities). glass, plastic, metallic elements, waste bags. Features: Chamber, lid and closure made of AISI-304 stainless steel Total control by microprocessor: Ten sterilization programs. Six programs are user free. 7 Litres feeding water reservoir. Automatic water filling. Automatic drying Includes RS-232 port to connect to a printer/PC. Safety: Safety valve and thermostat. Door hydraulic blocking system. Open lid sensor
Biological Safety Cabinet (class II, A2) Three protection: operator, sample and environment. Airflow system: 70% air re-circulation, 30% air exhaust. Suitable for working with microbiological research in the absence of volatile or toxic chemicals and radionuclide.
เป็นตู้ที่ใช้ทำความสะอาดร่างกายด้วยการเป่าลม สามารถช่วยกรองฝุ่นละอองหรือสิ่งสกปรกต่างๆก่อนเข้าไปในห้องปฏิบัติการแบบ Clean room ได้ ใช้ระบบกรองแบบ HEPA Filter ซึ่งสามารถกรองอนุภาคขนาด 0.3 ไมครอน ได้อย่างน้อย 99.999% มีระดับความสะอาด Class 100
-External size (WxDxH) 1500x760x2200 mm -Internal size (WxDxH) 1350x600x650 mm -Moterized front window. -Two layers laminated toughened glass >5mm, anti UV. -Time reserve function. -Interlock funtion. -Microprocessor control system. -HEPA filter life and UV life indicator. -0% air re-circulation, 100% air exhaust. -Automatic air speed adjustable with filter block. -Most accessories are standard. No need to pay more, save your money. -Work area surrounded by negative pressure, it can ensure maximum safety in work area. -Visual&Audio alarm when filter replacement, window over height, abnormal air flow velocity. -PVC exhaust duct, diameter 300 mm.
GeneMax is a PCR device to the new generation of the company. Since the company was founded 10 years of technology and performance of the peak of maximum feedback, is also 10 years to support our customers.
GeneMax adheres to FERROTEC's Peltier research and development, manufacture and application abili1y. Its performance and function has reached a new level, which can realize the perfect optimization for the annealing temperature. GeneMax is with l 0.4 inches large LCD touch screen, more convection for the man-machine interaction. It's efficient and stable by using ARM9 processor and ThreadX system. Moreover, GeneMax is launched with a gold-plated block at the first time. Its performance is more superior in temperaturecontrol. At the same time, Bluetooth signal converter can ealize wireless link between the instrument and computer.
AES Raypa autoclaves Intended use: Suitable to sterilize: culture media, glass, liquids, plastic, metallic elements,waste bags, etc. Total control by microprocessor External case, top, chamber and lid made of AISI-304 stainless steel. Supplied with protecting grid for the heater. Unsteaming pushbutton. Manual valve to drain. Safety valve and thermostat. Hydraulic door blocking system while existing positive pressure in the chamber. Open lid sensor
AHS-DRY Raypa autoclaves Intended use: Suitable to sterilize: wrapped or unwrapped solids, small porous elements and hollow elements type B (slightly deep and broad cavities). glass, plastic, metallic elements, waste bags. Features: Chamber, lid and closure made of AISI-304 stainless steel Total control by microprocessor: Ten sterilization programs. Six programs are user free. 7 Litres feeding water reservoir. Automatic water filling. Automatic drying Includes RS-232 port to connect to a printer/PC. Safety: Safety valve and thermostat. Door hydraulic blocking system. Open lid sensor
-Clean booth is a kind of air purifying equipment providing partial high clean environment, it’s the easiest and fastest way to build a simple clean room. -Equipped with a lot of clean level and space collocation, it can be designed as request. -Main characteristics: simple use, good flexibility, easy installation, short construction time, and movable. -It can be installed in part of clean room of general level which requires high cleanliness to save cost. -Class level : ISO 5 (class 100), class A. -Microprocessor control system. -Rectangular tube material : cold-rolled steel with anti-bacteria powder coating. -Wall material : anti-static dustproof curtain.
16 single tubes & strip tubes Customized TE module Top scanning mode Battery pack can be used as power supply Applicable in diversified and highly complicated application environment
16 single tubes & strip tubes Customized TE module Top scanning mode Battery pack can be used as power supply Applicable in diversified and highly complicated application environment
AES Raypa autoclaves Intended use: Suitable to sterilize: culture media, glass, liquids, plastic, metallic elements,waste bags, etc. Total control by microprocessor External case, top, chamber and lid made of AISI-304 stainless steel. Supplied with protecting grid for the heater. Unsteaming pushbutton. Manual valve to drain. Safety valve and thermostat. Hydraulic door blocking system while existing positive pressure in the chamber. Open lid sensor
AE-DRY Raypa autoclaves Intended use: Suitable to sterilize: unwrapped and wrapped solids, small porous objects and hollow ware type B (slightly deep and broad cavities), glass, plastic, liquids, metallic objects, waste bags. External case, top, chamber and lid made of AISI-304 stainless steel Total control by microprocessor Ten sterilization programs. Six programs are user free. Feeding water reservoir. Supplied with protecting grid for the heaters. Safety valve and thermostat. Hydraulic door blocking system while positive pressure exists in the chamber. Open lid sensor
-External size (WxDxH) 1800x750x2200 mm -Internal size (WxDxH) 1650x600x650 mm -Moterized front window. -Two layers laminated toughened glass >5mm, anti UV. -Time reserve function. -Interlock funtion. -Microprocessor control system. -HEPA filter life and UV life indicator. -0% air re-circulation, 100% air exhaust. -Automatic air speed adjustable with filter block. -Most accessories are standard. No need to pay more, save your money. -Work area surrounded by negative pressure, it can ensure maximum safety in work area. -Visual&Audio alarm when filter replacement, window over height, abnormal air flow velocity. -PVC exhaust duct, diameter 300 mm.
Nano-300 is an advanced model of Micro UV VIS Spectrophotometer based on Nano-100, with full range of wavelength (200-800nm). It is with an added new function of bacterium cell concentration measurement (OD600) in a cuvette. The Nano-300 only requires 0.5-2ul sample to measure nucleic acids, protein as quickly like Nano-100 do. Nano-300 come with a 7 inch touch screen and integranted Android operating system, with no computer required. It is an ideal equipment for a biology laboratory to make life science research more efficient.
-External size (WxDxH) 1350x750x2100 mm -Internal size (WxDxH) 1200x650x620 -Moterized front window. -Two layers laminated toughened glass >5mm, anti UV. -Microprocessor control system. -Air supply filter : ULPA filter, efficiency >99.999% for particle size at 0.12 µm. -Exhaust filter: 2 pieces HEPA filters, efficiency >99.999% for particle size at 0.3 µm (filter life and filter working time indicator). -Humidity and temperature can be displayed on the control panel. -Visual&Audio alarm when filter replacement, window over height, abnormal air flow velocity. -The PVC bag in and bag out filer can ensure the safety of the personal and the environment, and make the replacement process convenient and quick.
Easy control, 4L cold trap, Refrigeration systems reach -75C, Various tubes availabe, Oil status confirming in vacuum pump.
16 single tubes & strip tubes Customized TE module Top scanning mode Battery pack can be used as power supply Applicable in diversified and highly complicated application environment
AE-DRY Raypa autoclaves Intended use: Suitable to sterilize: unwrapped and wrapped solids, small porous objects and hollow ware type B (slightly deep and broad cavities), glass, plastic, liquids, metallic objects, waste bags. External case, top, chamber and lid made of AISI-304 stainless steel Total control by microprocessor Ten sterilization programs. Six programs are user free. Feeding water reservoir. Supplied with protecting grid for the heaters. Safety valve and thermostat. Hydraulic door blocking system while positive pressure exists in the chamber. Open lid sensor
Easy control, 4L cold trap, Refrigeration systems reach -75C, Various tubes availabe, Oil status confirming in vacuum pump.